Approval according to ATEX for mounting in explosion zones 1, 2, 21 and 22
Ex approved self-limiting heater band
Sold by the meter for on-site assembly or optionally factory-assembled according to your specifications
Inner tube is non-replaceable
Holding temperature at -20 °C [-4 °F] ambient temperature: +30 °C [+86 °F], temperature class T6
Max. length allowed for -20 °C [-4 °F] ambient temperature: 52 m
Available up to a length of 99 m
Inner tube made of PTFE with Ø DN 4/6
Outer jacket is a black corrugated PA hose
Operating pressure: max. 3 bar g
Electrical connection: for on-site assembly the heater band needs to be connected to an Ex terminal box, for factory assembly a 1 m long heater band is connected to an Ex e terminal box
Power: 230 V, 115 V available as option
Optionally: factory assembly, accessories for on-site assembly